{"id":5960,"date":"2024-02-28T18:10:04","date_gmt":"2024-02-28T18:10:04","guid":{"rendered":"https:\/\/afielektrik.com\/?post_type=product&p=5960"},"modified":"2024-03-14T08:45:34","modified_gmt":"2024-03-14T08:45:34","slug":"pb-pc-pl-floodlights","status":"publish","type":"product","link":"https:\/\/afielektrik.com\/en\/urun\/pb-pc-pl-floodlights\/","title":{"rendered":"PB, PC, PL Floodlights"},"content":{"rendered":"
\n
Flameproof<\/strong><\/div>\n
<\/div>\n
The PB, PC and PL Series provide flameproof lighting for indoor or outdoor use, offering a wide variety of lamp types, wattages and mounting options. These floodlights are ideally suited to the needs of oil and gas drilling, refining and transportation.<\/div>\n
<\/div>\n
ATEX \/ IECEx<\/div>\n
Zone 1 and 2 – 21 and 22<\/div>\n
ex\u00a0 II 2 GD<\/div>\n
IP66 or IP66\/67 – IK10<\/div>\n
NEC\/CEC:<\/div>\n
AEx\/Ex de IIB IP 66<\/div>\n
Ex de IIB<\/div>\n
IP 66<\/div>\n

Applications<\/strong><\/p>\n

\u2022 Enclosed and gasketed fixtures suitable for use in:
\n\u2014 Marine and wet locations
\n\u2014 Areas where flammable gases, vapors or combustible dusts are
\npresent under conditions defined by the IEC as Zone 2 and 22
\n\u2014 Applications where energy efficient, high lumen output is
\nrequired
\n\u2014 Non-hazardous locations where severe weather conditions,
\nexcessive moisture, dirt, dust, corrosive atmosphere or high
\nambient temperatures are encountered
\n\u2022 Typical applications include:
\n\u2014 Pulp and paper mills
\n\u2014 Processing plants
\n\u2014 Chemical plants
\n\u2014 Oil refineries
\n\u2014 Foundries
\n\u2014 Manufacturing plants
\n\u2014 Storage areas
\n\u2014 Waste and sewage treatment
\n\u2014 Other areas where dust, water, dirt and rough usage are a problem
\nFeatures:<\/strong>
\n\u2022 Power supply 230\/240 V (+6% – 10%) 50 Hz.
\n\u2022 Instant relighting with auxiliary halogen lamps, depending on \u00a0model (lamps not supplied).
\n\u2022 Fast relighting for 70 W and 150 W high pressure sodium: 5 \u00a0to 30 seconds depending on the duration of the mains power supply failure.
\n\u2022 Connection via terminal block \u2014 2 x 4 mm2<\/sup>\u00a0(0.003 x 0.006 in2<\/sup>) maximum.
\n\u2022 Superior corrosion-resistance: copperfree die-cast mounting\u00a0 hoods, ballast housing and guards have a gray epoxy powder\u00a0 coat, electrostatically applied for complete and uniform\u00a0 protection.
\n\u2022 Wide choice of light sources: high pressure sodium, metal\u00a0 halide, mercury vapor and incandescent.
\n\u2022 Six mounting arrangements to suit any lighting layout \u2013 pendant,\u00a0 ceiling, wall bracket, angled or straight stanchion and pendant\u00a0 cone (for dust applications).
\n\u2022 Hinge has high lip for added safety during installation and servicing. Hinge and bolt construction assures 360\u00b0
\ncompression at all points on ballast housing gasket for positive sealing. Swing away design of captive bolt and nut simplifies servicing.
\n\u2022 All fi xtures designed to perform in a -40 \u00b0C (-40 \u00b0F) ambient temperature up to +55 \u00b0C (+131 \u00b0F).
\n\u2022 Standard dome or 30\u00b0 angle reflectors made of fiberglass reinforced white polyester. Highly resistant to corrosive
\natmospheres and vented to improve fixture cooling characteristics.
\n\u2022 Fixture housing mounting hoods and guards are die-cast copperfree aluminum with epoxy powder coat finish.
\n\u2022 All exposed hardware is stainless steel and captive. Stainless thread inserts in the ballast bodies prevent \u201cfreezing\u201d of the screws that affix guards and reflectors, simplifying removal for service.
\n\u2022 One piece ballast housing for each component provides even heat dissipation for cooler operation and longer ballast life.
\n\u2022 Fixture bodies are provided with two silicone rubber O-Ring style gaskets that will stay flexible and assure even compression around their circumference. They easily withstand high temperatures, moisture, dirt and dust for worry free operation.<\/p>\n

\u00a0PB, PC, PL Series Floodlights\u00a0\u00a0\u00a0\u00a0<\/strong><\/div>\n
Flameproof. Incandescent and HID Lighting<\/div>\n
<\/div>\n
ATEX\/IECEx:<\/div>\n
Zone 1 and 2 – 21 and 22<\/div>\n
II 2 GD\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/em><\/div>\n
\n
IP66 or IP66\/67 \u2013 IK10<\/div>\n<\/div>\n
Ordering Information:<\/strong><\/div>\n
<\/div>\n
Ex de IIB Floodlight\u2013 PB Series<\/strong><\/div>\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\n
Lamp<\/strong><\/div>\n<\/td>\n
\n
Voltage<\/strong><\/div>\n<\/td>\n
\n
Lamp Type<\/strong><\/div>\n<\/td>\n
\n
Weight<\/strong><\/div>\n<\/td>\n
\n
Volume<\/strong><\/div>\n<\/td>\n
\n
<\/div>\n<\/td>\n<\/tr>\n
\n
Wattages<\/strong><\/div>\n<\/td>\n
\n
(V)<\/strong><\/div>\n<\/td>\n
\n
Elliptical<\/strong><\/div>\n<\/td>\n
\n
Tubular<\/strong><\/div>\n<\/td>\n
\n
kg<\/strong><\/div>\n<\/td>\n
\n
dm3<\/strong><\/div>\n<\/td>\n
\n
Catalog No.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
High Pressure Sodium<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
150 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
29.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAL15XJB<\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAL25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
31.8<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAL40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Mercury Vapor<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
29.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAM25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
29.8<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAM40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Metal Halide<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAH25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
31.8<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAH40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Halogen<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
500\/1000 W<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
26.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAZ50B<\/div>\n<\/td>\n<\/tr>\n
\n
2 x 70\u00a0 W<\/div>\n<\/td>\n
\n
24 Vac\/Vdc, 50 Hz<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
27.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PBAZ70BTB*<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 6.5 to 14.5 mm). Lamps are not included.<\/div>\n
* Supplied with 2 x 70 W H3 bulbs, 24 Vac\/Vdc<\/div>\n
<\/div>\n
Ex de IIC Floodlight\u2013 PC Series<\/strong><\/div>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\n
Lamp<\/strong><\/div>\n<\/td>\n
\n
Voltage<\/strong><\/div>\n<\/td>\n
\n
Lamp Type<\/strong><\/div>\n<\/td>\n
\n
Weight<\/strong><\/div>\n<\/td>\n
\n
Volume<\/strong><\/div>\n<\/td>\n
\n
<\/div>\n<\/td>\n<\/tr>\n
\n
Wattages<\/strong><\/div>\n<\/td>\n
\n
(V)<\/strong><\/div>\n<\/td>\n
\n
Elliptical<\/strong><\/div>\n<\/td>\n
\n
Tubular<\/strong><\/div>\n<\/td>\n
\n
kg<\/strong><\/div>\n<\/td>\n
\n
dm3<\/strong><\/div>\n<\/td>\n
\n
Catalog No.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
High Pressure Sodium<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
150 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
29.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAL15XJB<\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAL25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
32.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAL40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
600 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
35.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAL60XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Mercury Vapor<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAM25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.5<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAM40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Metal Halide<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAH25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
32.0<\/div>\n<\/td>\n
\n
104.4<\/div>\n<\/td>\n
\n
PCAH40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Halogen<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
500\/1000 W<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
27.0<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PCAZ50B<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 6.5 to 14.5 mm). Lamps are not included.<\/div>\n
<\/div>\n
Ex de IIB Floodlight\u2013 PL Series<\/strong><\/div>\n\n\n\n\n\n\n\n\n\n
\n
Lamp<\/strong><\/div>\n<\/td>\n
\n
Voltage<\/strong><\/div>\n<\/td>\n
\n
Lamp Type<\/strong><\/div>\n<\/td>\n
\n
Weight<\/strong><\/div>\n<\/td>\n
\n
Volume<\/strong><\/div>\n<\/td>\n
\n
<\/div>\n<\/td>\n<\/tr>\n
\n
Wattages<\/strong><\/div>\n<\/td>\n
\n
(V)<\/strong><\/div>\n<\/td>\n
\n
Elliptical<\/strong><\/div>\n<\/td>\n
\n
Tubular<\/strong><\/div>\n<\/td>\n
\n
kg<\/strong><\/div>\n<\/td>\n
\n
dm3<\/strong><\/div>\n<\/td>\n
\n
Catalog No.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
High Pressure Sodium<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
250 W<\/div>\n<\/td>\n
\n
230\/240 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
30.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PLAL25XJB<\/div>\n<\/td>\n<\/tr>\n
\n
400 W<\/div>\n<\/td>\n
\n
220 Vac, 50 Hz<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
31.8<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PLAL40XJB<\/div>\n<\/td>\n<\/tr>\n
\n
Halogen<\/strong><\/div>\n<\/td>\n<\/tr>\n
\n
500\/1000 W<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
—<\/div>\n<\/td>\n
\n
X<\/div>\n<\/td>\n
\n
26.3<\/div>\n<\/td>\n
\n
79.4<\/div>\n<\/td>\n
\n
PLAZ50B<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 6.5 to 14.5 mm). Lamps are not included.<\/div>\n

PB Series Floodlights Catalog Pages<\/a><\/p>\n<\/div>\n<\/div>\n\n

\n\n\t\t\n
    \n\t\t\t <\/ul>\n <\/div> \n","protected":false},"excerpt":{"rendered":"

    Flameproof The PB, PC and PL Series provide flameproof lighting for indoor or outdoor use, offering a wide variety of lamp types, wattages and mounting options. These floodlights are ideally suited to the needs of oil and gas drilling, refining and transportation. ATEX \/ IECEx Zone 1 and 2 –<\/p>\n","protected":false},"featured_media":5689,"template":"","meta":{"inline_featured_image":false},"product_cat":[93],"product_tag":[],"class_list":{"0":"post-5960","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hid","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/product\/5960"}],"collection":[{"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/media\/5689"}],"wp:attachment":[{"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/media?parent=5960"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/product_cat?post=5960"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/afielektrik.com\/en\/wp-json\/wp\/v2\/product_tag?post=5960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}